Resumen

Introduction. The specific aims of this study were to evaluate (1) the axial force reduction of suture passage utilizing electrocautery when applied to hip abductor repair, (2) the temperature change caused while using electrocautery for suture passage, and (3) the failure loads and failure modes utilizing this technique.

Methods. Five matched pairs of fresh-frozen femurs were used and classified into with electrocautery on needle (study group) and without electrocautery on needle (control group). Two bicortical osseous tunnels were made around the insertion of the gluteus medius tendon. Each specimen was sequentially tested in a needle penetration test and a single load-to-failure test. A No. 5 Ethibond suture with a straight needle was used.

Results. Electrocautery reduced the peak axial force for bone penetration in 40% (near cortex) and 70% (far cortex) of the trials, and no significant difference was detected between groups or between two osseous tunnels. The average peak force was significantly higher for the far cortex for both groups and for both osseous tunnels compared to the near cortex. There was no significant change in temperature of the tunnel site with electrocautery. 90% of the samples experienced bone tunnel failure for the study group compared to 70% in the control group. The average ultimate failure load for the study group was lower compared with the control group, but this finding was not statistically significant (range: 6%-15%).

Conclusions. Suture passage using electrocautery does not significantly decrease the peak force needed to pass a needle directly through the greater trochanter.

Métricas

##plugins.generic.paperbuzz.sourceName.fileDownloads##
107
Dec 31 '23Jan 01 '24Jan 04 '24Jan 07 '24Jan 10 '24Jan 13 '24Jan 16 '24Jan 19 '24Jan 22 '24Jan 25 '24Jan 28 '243.0
|

Descargas

Publicado

2023-12-31

Número

Sección

Brief Reports

Cómo citar

Staggers, J., Chong, A., Dahl, K., & Piatt, B. (2023). Use of Electrocautery to Facilitate Suture Passage Through the Greater Trochanter of the Femur: A Biomechanical Study. Kansas Journal of Medicine, 16(3), 316-320. https://doi.org/10.17161/kjm.vol16.21132